Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Rev Port Cardiol ; 42(6): 585-596, 2023 06.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36958578

RESUMO

INTRODUCTION: Heart failure (HF) is among the leading causes of morbidity and mortality worldwide. Several conditions trigger left ventricular chronic pressure or volume overload, hypertrophy, systolic and diastolic dysfunction, leading to cardiac remodeling and a rapid progression toward HF. Therapeutic interventions elicit reverse remodeling (RR), a highly variable myocardial response that ranges from none to total ventricular structural/functional recovery. However, HF patients present several comorbidities and medications that mask a comprehensive molecular knowledge of RR and hinder the identification of potential biomarkers of its progression or prognosis. Therefore, instead of using this heterogeneous population or even animal models to understand myocardial remodeling, we propose studying pregnancy-induced cardiovascular remodeling and postpartum-induced RR. OBJECTIVES: To assess cardiovascular functional and structural adaptations during pregnancy and in postpartum, characterizing the associated molecular changes; as well as to explore the impact of hypertension, obesity and diabetes on these processes. METHODS: We will perform echocardiography and assess endothelial function and arterial stiffness (EndoPAT® and pulse wave velocity, respectively) and assess potential markers of remodeling and RR using plasma and urine samples from pregnant women. To translate to a HF context, we will determine the impact of risk factors (hypertension, obesity and diabetes) by studying subgroups of pregnant women with these comorbidities. RESULTS: Not applicable. CONCLUSION: We are convinced that understanding the impact of these comorbidities in such a homogeneous population, such as pregnant women, provides a valuable model to unveil the most relevant pathologic and often masked signaling pathways underlying cardiac remodeling and incomplete RR in a heterogeneous population, such as HF patients. Moreover, we expect to identify potential novel biomarkers of RR progression/prognosis more easily.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Hipertensão , Animais , Feminino , Humanos , Gravidez , Estudos Prospectivos , Estudos de Coortes , Remodelação Ventricular/fisiologia , Análise de Onda de Pulso , Insuficiência Cardíaca/tratamento farmacológico , Obesidade , Biomarcadores , Função Ventricular Esquerda/fisiologia
3.
ABC., imagem cardiovasc ; 35(4): eabc346, 2022. tab, ilus
Artigo em Português | LILACS | ID: biblio-1425557

RESUMO

Introdução: A avaliação dos índices de trabalho miocárdico global em condições basais pode ser útil para a estratificação clínica de pacientes com suspeita de obstrução coronariana. Objetivo: Correlacionar o valor do índice de trabalho miocárdico global e a presença de lesões obstrutivas coronarianas significativas. Método: Estudo transversal, com pacientes encaminhados para cinecoronarioangiografia eletiva. Foi realizado ecocardiograma com obtenção das medidas para cálculo do valor do trabalho miocárdico, sendo avaliada a presença de lesões obstrutivas coronarianas significativas à cinecoronarioangiografia. Resultados: A amostra foi composta de 30 pacientes, com a idade média de 64,2±12,8 anos, sendo a maioria do sexo masculino (63,3%), dos quais 68,4% apresentaram lesões obstrutivas coronarianas significativas. O índice de trabalho miocárdico global foi de 1.876mmHg%±253,8 no grupo com lesões obstrutivas coronarianas significativas e de 2.054,2mmHg%±417,3 naqueles sem lesões significativas (p=0,089). O trabalho miocárdio construtivo global nos pacientes sem lesões obstrutivas coronarianas significativas foi maior (2.329,3mmHg%±462,9) do que naqueles com lesões obstrutivas coronarianas significativas (2.109,5mmHg%±332,3; p=0,064). O trabalho miocárdio desperdiçado global foi maior nos pacientes com lesões obstrutivas coronarianas significativas (103,7mmHg%±47,1 versus 68,3mmHg%±33,8; p=0,038). O ponto de corte de 115mmHg% foi aquele com a melhor área sob a curva (0,625), com sensibilidade de 83,3%. Conclusão: O aumento do trabalho miocárdio desperdiçado global se correlacionou com a presença de lesões obstrutivas coronarianas significativas em nossa amostra.(AU)


Introduction: The assessment of global myocardial work indices under baseline conditions may be useful for the clinical stratification of patients with suspected coronary obstruction. Objective: To correlate the value of global myocardial work indices and the presence of significant obstructive coronary lesions. Method: Cross-sectional study, with patients referred for elective coronary angiography. An echocardiogram was performed to obtain measurements to calculate the value of myocardial work and evaluated the presence or presence of significant obstructive coronary lesions at coronary angiography. Results: The sample consisted of 30 patients, with a mean age of 64.2±12.8 years, the majority being male (63.3%), of which 68.4% had significant obstructive coronary lesions. The global myocardial work indices was 1,876mmHg%±253.8 in the group with significant obstructive coronary lesions and 2,054.2mmHg%±417.3 in those without significant lesions (p=0.089). Global constructive myocardial work in patients without significant obstructive coronary lesions was higher (2,329.3mmHg%±462.9) than in those with significant obstructive coronary lesions (2,109.5mmHg%±332.3; p=0.064). Global wasted myocardial work was higher in patients with significant obstructive coronary lesions (103.7mmHg%±47.1 versus 68.3mmHg%±33.8; p=0.038). The cutoff point of 115 mmHg% was the one with the best area under the curve (0.625), with a sensitivity of 83.3%. Conclusion: The increase in global wasted myocardial work correlated with the presence of significant obstructive coronary lesions in our sample. (AU)


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Ventrículos do Coração/lesões , Ecocardiografia/métodos , Cateterismo Cardíaco/métodos , Estenose Coronária/fisiopatologia , Ecocardiografia sob Estresse/métodos , Testes de Função Cardíaca/métodos
5.
Rev. bras. med. esporte ; 27(4): 358-362, Aug. 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1288604

RESUMO

ABSTRACT Introduction: A new exercise electrocardiogram (ECG) detection system was investigated in this study to diagnose and analyze cardiopulmonary function and related diseases in a comprehensive and timely manner and improve the accuracy of diagnosis. Besides, its reliability and clinical applicability were judged. Objective: A new type of exercise ECG detection system was constructed by adding parameters such as respiratory mechanics, carbon dioxide, and oxygen concentration monitoring based on the traditional ECG detection system. Methods: The new system constructed in this study carried out the ECG signal detection, ECG acquisition module, blood pressure and respiratory mechanics detection and conducted a standard conformance test. Results: The heart rate accuracy detected by the exercise ECG system was greatly higher than that of the doctor's manual detection (P < 0.05). The accuracy of the new exercise ECG detection system increased obviously in contrast to that of the manual detection result (P < 0.05). The key technical index input noise and input impedance test results (24.5 μV and 12.4 MΩ) of the exercise ECG detection system conformed to the standard (< 30 μV and > 2.5 MΩ). The common-mode rejection and sampling rate test results (103.5 dB and 515 Hz) of key technical indicators in the exercise ECG detection system were all in line with the standards (≥89 dB and ≥500 Hz). Conclusion: The complete exercise ECG detection system was constructed through the ECG acquisition module, blood pressure detection, and respiratory mechanics detection module. In addition, this system could be applied to detect ECG monitoring indicators with high accuracy and reliability, which could also be extensively adopted in clinical diagnosis. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: Um novo sistema de detecção de eletrocardiograma de exercício (ECG) foi investigado neste estudo para diagnosticar e analisar a função cardiopulmonar e doenças relacionadas de maneira abrangente e oportuna e melhorar a precisão do diagnóstico. Além disso, sua confiabilidade e aplicabilidade clínica foram julgadas. Objetivo: Um novo tipo de sistema de detecção de ECG de esforço foi construído adicionando parâmetros como mecânica respiratória, dióxido de carbono e monitoramento da concentração de oxigênio com base no sistema de detecção de ECG tradicional. Métodos: O novo sistema construído neste estudo realizou a detecção do sinal de ECG, módulo de aquisição de ECG e detecção de pressão arterial e mecânica respiratória, e conduziu um teste de conformidade padrão. Resultados: A precisão da frequência cardíaca detectada pelo sistema de ECG de esforço foi muito maior do que a detecção manual do médico (P <0,05). A precisão do novo sistema de detecção de ECG de esforço aumentou obviamente em contraste com o resultado da detecção manual (P <0,05). O ruído de entrada do índice técnico principal e os resultados do teste de impedância de entrada (24,5 μV e 12,4 MΩ) do sistema de detecção de ECG de esforço estão em conformidade com o padrão (<30 μV e> 2,5 MΩ). A rejeição do modo comum e os resultados do teste de taxa de amostragem (103,5 dB e 515 Hz) dos indicadores técnicos principais no sistema de detecção de ECG de esforço estavam todos alinhados com os padrões (≥89 dB e ≥500 Hz). Conclusão: O sistema completo de detecção de ECG de esforço foi construído através da combinação de módulo de aquisição de ECG, detecção de pressão arterial e módulo de detecção de mecânica respiratória. Além disso, esse sistema poderia ser aplicado à detecção de indicadores de monitoramento de ECG com alta precisão e confiabilidade, o que poderia ser amplamente adotado no diagnóstico clínico. Nível de evidência II; Estudos terapêuticos- investigação dos resultados do tratamento.


RESUMEN Introducción: En este estudio se investigó un nuevo sistema de detección de electrocardiograma de esfuerzo (ECG) para diagnosticar y analizar la función cardiopulmonar y enfermedades relacionadas de manera integral y oportuna, y mejorar la precisión del diagnóstico. Además, se evaluó su confiabilidad y aplicabilidad clínica. Objetivo: Se construyó un nuevo tipo de sistema de detección de ECG de ejercicio agregando parámetros como la mecánica respiratoria, el dióxido de carbono y el monitoreo de la concentración de oxígeno sobre la base del sistema de detección de ECG tradicional. Métodos: El nuevo sistema construido en este estudio llevó a cabo la detección de la señal de ECG, el módulo de adquisición de ECG y la detección de la presión arterial y la mecánica respiratoria, y realizó una prueba de conformidad estándar. Resultados: la precisión de la frecuencia cardíaca detectada por el sistema de ECG de ejercicio fue mucho mayor que la de la detección manual del médico (P <0,05). La precisión del nuevo sistema de detección de ECG de esfuerzo aumentó obviamente en contraste con el resultado de la detección manual (P <0.05). Los resultados de la prueba de impedancia de entrada y ruido de entrada de índice técnico clave (24,5 μV y 12,4 MΩ) del sistema de detección de ECG de esfuerzo cumplieron con el estándar (<30 μV y> 2,5 MΩ). Los resultados de la prueba de frecuencia de muestreo y rechazo en modo común (103,5 dB y 515 Hz) de los indicadores técnicos clave en el sistema de detección de ECG de esfuerzo estaban en línea con los estándares (≥89 dB y ≥500 Hz). Conclusión: El sistema completo de detección de ECG de ejercicio se construyó mediante la combinación del módulo de adquisición de ECG, la detección de la presión arterial y el módulo de detección de la mecánica respiratoria. Además, este sistema podría aplicarse a la detección de indicadores de monitoreo de ECG con alta precisión y confiabilidad, que también podría adoptarse ampliamente en el diagnóstico clínico. Nivel de evidencia II; Estudios terapéuticos- investigación de los resultados del tratamiento.


Assuntos
Eletrocardiografia/métodos , Teste de Esforço , Testes de Função Cardíaca/instrumentação , Reprodutibilidade dos Testes
6.
Rev. bras. med. esporte ; 27(8): 822-825, Aug. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1351840

RESUMO

ABSTRACT Introduction: The study and collection of athletes' heart function index parameters and the correct and reasonable evaluation of body functions can effectively adjust training plans and avoid athletes' bodily exhaustion. Objective: To study the diagnosis of myocardial injury by cardiovascular monitoring in athletes from two aspects: extraction of characteristic parameters of heart function and research of signal processing. Methods: The heart function intelligent evaluation algorithm was studied by using multi-source information fusion, and embedded technology; miniature sensors were used as well. Results: The incidence of severe ventricular arrhythmia was lower in both groups. The incidence of sinus arrhythmia and intermittent second degree I atrioventricular block in the high-intensity group was significantly higher than that in the control group. The number of atrial and ventricular premature beats was lower in the control group, but increased significantly in the high-intensity group. Conclusions: This study applied the theory of multi-source information fusion to carry out representative research on the intelligent monitoring and evaluation of the heart function of elite athletes, centering on the application requirements of the heart function monitoring of elite athletes. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: O estudo e a coleta de parâmetros indiciais da função cardíaca em atletas e a avaliação correta e razoável das funções corporais podem, efetivamente, levar ao ajuste de planos de treinamento e evitar a sobrecarga física de atletas. Objetivo: Estudar o diagnóstico da lesão miocárdica pelo monitoramento cardiovascular em atletas a partir de dois aspectos: a extração de parâmetros característicos da função cardíaca e a pesquisa do processamento de sinais. Métodos: O algoritmo de avaliação inteligente da função cardíaca foi estudado usando a fusão de informações de múltiplas fontes, além da tecnologia embarcada. Sensores em miniatura também foram usados. Resultados: A incidência de arritmia ventricular severa era menor nos dois grupos. A incidência de arritmia sinusal e o bloqueio atrioventricular de segundo grau do tipo I intermitente no grupo de alta intensidade foi significativamente mais alta do que no grupo de controle. O número de batidas prematuras atriais e ventriculares era menor no grupo de controle, mas aumentava consideravelmente no grupo de alta intensidade. Conclusões: Este estudo aplicou a teoria da fusão de informações de múltiplas fontes para conduzir uma pesquisa importante sobre o monitoramento e avaliação inteligentes da função cardíaca de atletas de elite, enfocando as exigências de aplicação do monitoramento da função cardíaca de atletas de elite. Nível de evidência II; Estudos terapêuticos - investigação de resultados de tratamento.


RESUMEN Introducción: El estudio y la recogida de parámetros indíciales de la función cardíaca en atletas y la evaluación correcta y razonable de las funciones corporales pueden efectivamente llevar al ajuste de planes de entrenamiento y evitar la sobrecarga física de atletas. Objetivo: Estudiar el diagnóstico de la lesión miocárdica a través del monitoreo cardiovascular en atletas a partir de dos aspectos: la extracción de parámetros característicos de la función cardíaca y la investigación del procesamiento de señales. Métodos: El algoritmo de evaluación inteligente de la función cerebral se estudió utilizando la fusión de informaciones de múltiples fuentes, además de la tecnología embebida. Sensores en miniatura también se utilizaron. Resultados: La incidencia de taquicardia ventricular severa era menor en los dos grupos. La incidencia de arritmia sinusal y bloqueo auriculoventricular de segundo grado del tipo I intermitente en el grupo de alta intensidad fue significativamente más alta que en el grupo de control. El número de contracciones prematuras auriculares y ventriculares era menor en el grupo de control, pero aumentaba considerablemente en el grupo de alta intensidad. Conclusiones: Este estudio aplicó la teoría de la fusión de informaciones de múltiples fuentes para conducir una investigación importante sobre el monitoreo y evaluación inteligentes de la función cardiaca de atletas de élite, centrando las exigencias de aplicación del monitoreo de la función cardíaca de atletas de élite. Nivel de evidencia II; Estudios terapéuticos - investigación de resultados de tratamiento.

7.
ABC., imagem cardiovasc ; 34(4): eabc256, 2021. tab
Artigo em Português | LILACS | ID: biblio-1359750

RESUMO

Fundamento: A ecocardiografia transtorácica (ETT) pode desempenhar um papel crucial na avaliação das manifestações cardíacas da COVID-19. Objetivo: Nosso objetivo foi relatar a prevalência das principais anormalidades ecocardiográficas em pacientes hospitalizados com COVID-19. Métodos: Realizou-se estudo observacional multicêntrico prospectivo com pacientes com COVID-19 submetidos a ETT durante a internação. Pacientes com insuficiência cardíaca prévia, doença arterial coronariana ou fibrilação atrial foram classificados como portadores de doença cardiovascular (DCV) prévia. Foram coletados dados clínicos e ecocardiográficos da estrutura e da função cardíaca. Resultados: Avaliamos 310 pacientes com COVID-19, com 62±16 anos de idade, 61% homens, 53% com hipertensão arterial, 33% com diabetes e 23% com DCV prévia. No total, 65% dos pacientes necessitaram de suporte em unidade de terapia intensiva. As alterações ecocardiográficas mais prevalentes foram hipertrofia do ventrículo esquerdo (VE) (29%), hipertensão pulmonar (25%), disfunção sistólida do VE (16,5%), disfunção sistólica do ventrículo direito (VD) (15,9%), disfunção diastólica do VE grau II/III (11%) e alteração da contratilidade regional do VE (11%). Derrame pericárdico foi incomum (7%). Hipertrofia do VE (25 vs. 45%, p=0,001), disfunção sistólica do VE (11 vs. 36%, p<0,001), alterações da contratilidade regional (6 vs. 29%, p<0,001), disfunção diastólica do VE grau II/III (9 vs. 19%, p=0,03) e hipertensão pulmonar (22 vs. 36%, p=0,019) foram menos comuns nos pacientes sem do que com DCV prévia. A disfunção sistólica do VD mostrou-se semelhante em pacientes sem e com DCV prévia (13 vs. 25%, p=0,07). Conclusões: Entre os pacientes hospitalizados com COVID-19, os achados ecocardiográficos anormais foram comuns, porém menos encontrados naqueles sem DCV. A disfunção sistólica do VD pareceu afetar de forma semelhante pacientes com e sem DCV prévia. (AU)


Background: Transthoracic echocardiography (TTE) may play a crucial role in the evaluation of cardiac manifestations of coronavirus disease 2019 (COVID-19). Objective: We aimed to report the prevalence of the main echocardiographic abnormalities of hospitalized COVID-19 patients. Methods: We performed a prospective multicenter observational study in patients with COVID-19 who underwent TTE during hospitalization. Patients with pre-existing heart failure, coronary artery disease, or atrial fibrillation were categorized as having previous cardiovascular disease (CVD). Clinical and echocardiographic data about cardiac structure and function were collected. Results: We evaluated 310 patients with COVID-19 (mean age, 62±16 years; 61% men; 53% with arterial hypertension; 33% with diabetes; and 23% with previous CVD). Overall, 65% of the patients required intensive care unit support. The most prevalent echocardiographic abnormalities were LV hypertrophy (29%), pulmonary hypertension (25%), left ventricular (LV) systolic dysfunction (16.5%), right ventricular (RV) systolic dysfunction (15.9%), grade II/III LV diastolic dysfunction (11%), and LV regional wall motion abnormality (11%). Pericardial effusion was uncommon (7% of cases). LV hypertrophy (25% vs. 45%, p=0.001), LV systolic dysfunction (11% vs. 36%, p<0.001), regional wall motion abnormalities (6% vs. 29%, p<0.001), grade II/III LV diastolic dysfunction (9% vs. 19%, p=0.03), and pulmonary hypertension (22% vs. 36%, p=0.019) were less common in patients without previous CVD. RV systolic dysfunction occurred at similar frequencies in patients with versus without previous CVD (13% vs. 25%, p=0.07). Conclusions: Among patients hospitalized with COVID-19, abnormal echocardiographic findings were common, but less so among those without previous CVD. RV systolic dysfunction appeared to affect similar proportions of patients with versus without previous CVD. (AU)


Assuntos
Humanos , Masculino , Adolescente , Adulto , Pessoa de Meia-Idade , Ecocardiografia/estatística & dados numéricos , COVID-19/complicações , COVID-19/fisiopatologia , COVID-19/diagnóstico por imagem , Insuficiência Cardíaca/classificação , Doenças Cardiovasculares/história , Fatores Epidemiológicos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Diabetes Mellitus/história , Hipertensão/história , Hipertensão Pulmonar/diagnóstico por imagem
8.
Rev. méd. Paraná ; 79(2): 36-39, 2021.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1368399

RESUMO

O lúpus eritematoso sistêmico (LES) é doença autoimune crônica. Uma das suas importantes complicações é o dano cardiovascular. O objetivo deste trabalho foi estudar a prevalência de disfunção cardíaca em uma população local com LES e verificar se o grau de disfunção está associado com o a atividade da doença medida pelo SLEDAI (Systemic Lupus erythematosus activity index). Foram selecionados 19 pacientes assintomáticos do ponto de vista cardiovascular com diagnóstico de LES e que preenchiam os critérios classificatórios. A atividade de doença foi medida pelo SLEDAI e a função cardíaca por ecocardiografia transtorácica. Em conclusão, não foi possível identificar disfunção cardíaca na amostra estudada. Pontuações mais altas no índice de atividade do lúpus demonstraram correlação com aumento de massa de ventrículo esquerdo e fração de ejeção.


Systemic lupus erythesis (SLE) is a chronic autoimmune disease. One of the important complications of this disease is the cardiovascular damage The objective of this work was to study the prevalence of cardiac dysfunction in a local population with SLE and to verify whether the degree of dysfunction is associated with the disease activity measured by SLEDAI (Systemic Lupus erythematosus activity index). Were selected 19 patients asymptomatic from cardiovascular point of view diagnosed with SLE and who met the classification criteria for SLE. Disease activity was measured by SLEDAI and cardiac function was evaluated by transthoracic echocardiography. In conclusion, cardiac dysfunction could not be identified in the sample studied. Higher scores in the lupus activity index showed a correlation with increased left ventricle mass and ejection fraction.

9.
Arq. bras. med. vet. zootec. (Online) ; 72(5): 1577-1585, Sept.-Oct. 2020. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1131560

RESUMO

This study aimed to evaluate the impact of minimally invasive partial pericardiotomy on echocardiographic variables of morphometry and function in healthy horses. Minimally invasive pericardiotomy was performed in six healthy horses. Echocardiographic evaluation was executed in different moments: prior to the surgical procedure (M0); 24 hours post procedure (M1); 72 hours post procedure (M2) and 28 days post procedure (M3). The following variables were measured: Right ventricular internal diameter in diastole and systole (RVd and RVs), interventricular septum thickness in diastole and systole (IVSd and IVSs), left ventricular internal diameter in diastole and systole (LVd and LVs), left ventricular free wall thickness in diastole and systole (LVFWd and LVFWs), aortic root diameter (Ao) and left atrial diameter (LA). From this data, the following variables were calculated: fractional shortening (FS%), fractional thickening of the interventricular septum (IVS%), fractional thickening of the left ventricular free wall (LVFW%) and the relationship between left atrial and aortic diameters (LA/Ao). After 28 days, a new thoracoscopy was performed for inspection of the thoracic cavity. In M1 and M2 ECO evaluations, a statistically significant change in LVFW and a decrease in RVd, LVd, LVFWs, LA, LVs, FS% and IVS was documented. Pericardiotomy is a promising technique in horses, with minor postoperative complication. The variations in the echocardiographic parameters were transient and did not cause hemodynamic damage to the animals.(AU)


O objetivo do presente estudo foi avaliar o impacto da pericardiotomia parcial minimamente invasiva sobre as variáveis ecocardiográficas morfométricas e funcionais em cavalos, visto que não há nenhum trabalho que tenha avaliado o impacto da pericardiotomia na espécie equina. Foram utilizados seis cavalos hígidos, nos quais se realizou pericardiotomia minimamente invasiva. Em todos eles, foi efetuado exame ecocardiográfico em diferentes momentos: previamente ao procedimento cirúrgico (M0); 24 horas após (M1); 72 horas após (M2) e 28 dias após (M3). Foram mensurados: diâmetro interno do ventrículo direito (VDd e VDs), espessura do septo interventricular (SIVd e SIVs), diâmetro interno do ventrículo esquerdo (VEd e VEs), espessura da parede livre do ventrículo esquerdo (PLVEd e PLVEs), diâmetro interno da aorta (Ao) e diâmetro atrial esquerdo (AE). Foram calculadas as variáveis fração de encurtamento (FEC%), espessamento fracional do septo interventricular (SIV%), espessamento fracional da parede livre do ventrículo esquerdo (PLVE%) e relação entre diâmetro do átrio esquerdo e diâmetro aórtico (AE/Ao). Após 28 dias, realizou-se nova toracoscopia para inspeção da cavidade torácica. Nas avaliações do ECO no M1 e no M2, houve alteração estatisticamente significativa no PLVE em diástole (28±5,5 e 31,7±2, respectivamente) e diminuição dos parâmetros VDd,(30,1±11,6 e 31,7± 10,7) VEd (113,3±21 e 121,7±13,7), PLVEs (42±8,2 e 43,9±2,8), AE (78,5±6,1 e 82,7±4,7), VEs (74,1±16 e 71,5±9,3), FEC (34,4±10,2 e 41,2±5,7) e SIV (27,1±8,7 e 42,3±27,9). A técnica de pericardiotomia empregada mostrou-se promissora em equinos. As variações dos parâmetros ecocardiográficos foram transitórias, não causando prejuízos hemodinâmicos aos animais.(AU)


Assuntos
Animais , Pericardiectomia/veterinária , Testes de Função Cardíaca/veterinária , Cavalos/cirurgia , Toracoscopia/veterinária , Ecocardiografia/veterinária
10.
J. pediatr. (Rio J.) ; 95(4): 475-481, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1040340

RESUMO

Abstract Objective: Mucopolysaccharidosis is a rare genetic disease characterized by the intralysosomal deposition of glycosaminoglycans. Cardiovascular impairment is a common feature. Cardiac signs and symptoms are underestimated due to the disease involvement in other organs. Enzyme replacement therapy can be used in mucopolysaccharidosis I, II, IV, and VI. Thus, the knowledge about the use of new echocardiography tools is relevant to improve the care of this population. This study aimed to describe left ventricular function assessment by conventional echocardiography and left ventricular global longitudinal strain analysis and compare the alterations in patients receiving enzyme replacement therapy and who had different ages at the start of therapy. Method: Outpatient-based descriptive study. The patients were submitted to conventional echocardiography and left ventricular global longitudinal strain measurement. Results: Sixteen patients were evaluated; median age of 14.2 years (SD = 5.2 years). Left ventricular hypertrophy was found in nine patients (56.2%). All patients had preserved left ventricular systolic function (Simpson and Teichholz). Nine (56.2%) patients showed alterations in left ventricular global longitudinal strain. The study showed a positive association between left ventricular hypertrophy and alteration in the left ventricular global longitudinal strain, and late start of enzyme replacement therapy and alteration in the left ventricular global longitudinal strain. Conclusion: Echocardiographic alterations in patients with mucopolysaccharidosis were frequently observed, especially alterations in the left ventricular geometry and subclinical dysfunction. Patients who had a late enzyme replacement therapy start showed an association with worse left ventricular global longitudinal strain values, reinforcing the need for early diagnosis and treatment. The use of new echocardiographic tools may improve the follow-up of these patients.


Resumo Objetivo: A mucopolissacaridose é uma doença genética rara, caracterizada por depósito intralisossômico de glicosaminoglicanos. O comprometimento cardiovascular é frequente. Sinais e sintomas cardíacos são subestimados pelo envolvimento da doença em outros órgãos. A terapia de reposição enzimática pode ser usada em mucopolissacaridose I, II, IV e VI. Assim, o conhecimento da aplicação de novas ferramentas de ecocardiografia é relevante para melhorar a assistência dessa população. Este estudo visou descrever a função do ventrículo esquerdo pelo ecocardiograma convencional e pela análise do strain global longitudinal do ventrículo esquerdo e comparar as alterações em pacientes que fazem uso da terapia de reposição enzimática e que tiveram idades distintas de início da terapia. Método: Estudo descritivo de base ambulatorial. Os pacientes foram submetidos à ecocardiografia convencional e medida do strain global longitudinal do ventrículo esquerdo. Resultados: Foram avaliados 16 pacientes; mediana de 14,2 anos (desvio: 5,2 anos). Hipertrofia do ventrículo esquerdo foi encontrada em nove pacientes (56,2%). Todos os pacientes tiveram função sistólica do ventrículo esquerdo preservada (Simpson e Teichholz). Nove (56,2%) pacientes apresentaram alteração no strain global longitudinal do ventrículo esquerdo. O estudo mostrou associação positiva entre hipertrofia do ventrículo esquerdo e alteração no strain global longitudinal do ventrículo esquerdo e início tardio da terapia de reposição enzimática e alteração no strain global longitudinal do ventrículo esquerdo. Conclusão: Alterações ecocardiográficas em pacientes com mucopolissacaridose foram frequentes, especialmente alterações na geometria e disfunção subclínica do ventrículo esquerdo. Pacientes que iniciaram tardiamente a terapia de reposição enzimática apresentaram associação com piores valores de strain global longitudinal do ventrículo esquerdo, o que reforça a necessidade do diagnóstico e tratamento precoces. O uso de novas ferramentas de ecocardiografia pode melhorar o acompanhamento desses pacientes.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Mucopolissacaridoses/complicações , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Miocárdio/patologia , Ecocardiografia/métodos , Estudos Transversais , Mucopolissacaridoses/tratamento farmacológico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/tratamento farmacológico , Terapia de Reposição de Enzimas
11.
J Pediatr (Rio J) ; 95(4): 475-481, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29957247

RESUMO

OBJECTIVE: Mucopolysaccharidosis is a rare genetic disease characterized by the intralysosomal deposition of glycosaminoglycans. Cardiovascular impairment is a common feature. Cardiac signs and symptoms are underestimated due to the disease involvement in other organs. Enzyme replacement therapy can be used in mucopolysaccharidosis I, II, IV, and VI. Thus, the knowledge about the use of new echocardiography tools is relevant to improve the care of this population. This study aimed to describe left ventricular function assessment by conventional echocardiography and left ventricular global longitudinal strain analysis and compare the alterations in patients receiving enzyme replacement therapy and who had different ages at the start of therapy. METHOD: Outpatient-based descriptive study. The patients were submitted to conventional echocardiography and left ventricular global longitudinal strain measurement. RESULTS: Sixteen patients were evaluated; median age of 14.2 years (SD=5.2 years). Left ventricular hypertrophy was found in nine patients (56.2%). All patients had preserved left ventricular systolic function (Simpson and Teichholz). Nine (56.2%) patients showed alterations in left ventricular global longitudinal strain. The study showed a positive association between left ventricular hypertrophy and alteration in the left ventricular global longitudinal strain, and late start of enzyme replacement therapy and alteration in the left ventricular global longitudinal strain. CONCLUSION: Echocardiographic alterations in patients with mucopolysaccharidosis were frequently observed, especially alterations in the left ventricular geometry and subclinical dysfunction. Patients who had a late enzyme replacement therapy start showed an association with worse left ventricular global longitudinal strain values, reinforcing the need for early diagnosis and treatment. The use of new echocardiographic tools may improve the follow-up of these patients.


Assuntos
Mucopolissacaridoses/complicações , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Adolescente , Criança , Estudos Transversais , Ecocardiografia/métodos , Terapia de Reposição de Enzimas , Feminino , Humanos , Masculino , Mucopolissacaridoses/tratamento farmacológico , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Esquerda/fisiopatologia
12.
Pesqui. vet. bras ; 38(5): 997-1004, May 2018. tab, graf
Artigo em Português | LILACS, VETINDEX | ID: biblio-955419

RESUMO

Objetivou-se com este estudo reportar descrições acerca dos cortes ecocardiográficos no modo bidimensional, das dimensões cardíacas pelo modo unidimensional e dos índices de fluxo Doppler em caprinos da raça Moxotó. Foram utilizados 32 caprinos da raça Moxotó, distribuídos em quatro grupos por categoria de peso corporal, de igual número (n=8), em: G1 (5-10kg), G2 (10-15kg), G3 (15-20kg) e G4 (>20kg). Todos foram submetidos a um registro ecocardiográfico pelos modos bidimensional, modo-M, Doppler pulsado (PW), contínuo (CW) e de fluxo de cores (CF). A formação espectral das imagens ecocardiográficas foi satisfatória, contudo algumas adaptações foram necessárias para obtenção adequada dos cortes nos caprinos acima de 20 kg. Os parâmetros ecocardiográficos em modo unidimensional (IVSd, IVSs, LVIDd, LVIDs, VPWd, LVPWs) e índices de função cardíaco (EF e FS) apresentaram uma correlação descritiva positiva com peso corporal enquadradas nas categorias estudadas. A separação septal do ponto E, mostrou-se constante dentre as categorias de peso investigadas, variando entre 0,1 a 0,41cm em caprinos da raça Moxotó. A relação Em/Am foi predominantemente " >1" em todos os caprinos estudados, com Emax > Amax em todas as categorias, não sendo sujeito a influência da frequência cardíaca dentre as categorias de peso estudados. O mesmo pode ser aplicado ao TRIV, que se mostrou uniforme dentre os intervalos de peso estudados. As velocidades de fluxo da valva aórtica individuais foram superiores a velocidade máxima do fluxo da valva pulmonar. Os tempos de ejeção dos fluxos aórtico e pulmonar apresentaram correlação positiva descritiva com o aumento do peso corporal. Condição também observada sobre o VTI dos espectros de fluxo, dada a relação direta desta variável com o volume sistólico inversamente à FC. O tempo de aceleração (TA) do fluxo pulmonar foi superior ao fluxo aórtico, sendo este relação direta com aumento do peso corporal por categoria estudada e inversamente à frequência cardíaca. Desta forma, a padronização das variáveis ecodopplercardiográficas na espécie caprina, deve sempre considerar particularidades relacionadas ao padrão racial, faixa etária e peso corporal, bem como estudos de repetibilidade e reprodutibilidade e adoção de elementos individuais referenciais para elaboração confiável de valores de normalidade.(AU)


This study describes the two-dimensional echocardiographic sections, M-mode cardiac dimensions, and Doppler flow indices in Moxotó goats. A total of 32 Moxotó goats were divided into four equal groups (n = 8) according to body weight class: G1 (5-10 kg), G2 (10-15kg), G3 (15-20kg) and G4 (>20kg). All animals underwent echocardiographic tests, two-dimensional and M-mode, and pulsed (PW), continuous (CW) and color flow (CF) Doppler. The spectral formation of echocardiographic images was satisfactory, although some adjustments were necessary to obtain adequate cuts/sections for goats above 20 kg. One-dimensional echocardiographic parameters (IVSD, IVSS, LVIDd, LVIDs, VPWd, LVPWs) and cardiac function index (EF and FS) showed a positive descriptive correlation with body weight in the categories studied. The septal separation of point E was constant among the weight categories investigated, ranging from 0.1 to 0.41cm. The Em/Am ratio was predominantly ">1", with Emax> Amax in all weight categories, and not affected by the heart rate among the studied weight classes. The IVRT was also uniform among the studied weight classes. The individual flow rates of the aortic valve were higher than the maximum flow rate of the pulmonary valve. The ejection times of the aortic and pulmonary flows were positively correlated with increasing body weight, something also observed on the VTI of flow spectra, given the direct relationship of this variable with the stroke volume inversely to FC. The acceleration time (AT) of pulmonary blood flow was greater than the aortic flow, and directly related to increasing body weight and inversely with heart rate. Thus, the standardization of Doppler echocardiographic variables in goats, should always consider breed, age and body weight as well as repeatability and reproducibility studies and adoption of individual reference elements for reliable development of normal values.(AU)


Assuntos
Animais , Ruminantes/classificação , Ecocardiografia Doppler/veterinária , Peso Corporal
13.
Arq. bras. cardiol ; 109(5): 432-439, Nov. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-887955

RESUMO

Abstract Background: Different types of high-fat and/or high-energy diets have been used to induce obesity in rodents. However, few studies have reported on the effects observed at the initial stage of obesity induced by high-fat feeding on cardiac functional and structural remodelling. Objective: To characterize the initial moment of obesity and investigate both metabolic and cardiac parameters. In addition, the role of Ca2+ handling in short-term exposure to obesity was verified. Methods: Thirty-day-old male Wistar rats were randomized into two groups (n = 19 each): control (C; standard diet) and high-fat diet (HF, unsaturated high-fat diet). The initial moment of obesity was defined by weekly measurement of body weight (BW) complemented by adiposity index (AI). Cardiac remodelling was assessed by morphological, histological, echocardiographic and papillary muscle analysis. Ca2+ handling proteins were determined by Western Blot. Results: The initial moment of obesity occurred at the 3rd week. Compared with C rats, the HF rats had higher final BW (4%), body fat (20%), AI (14.5%), insulin levels (39.7%), leptin (62.4%) and low-density lipoprotein cholesterol (15.5%) but did not exhibit alterations in systolic blood pressure. Echocardiographic evaluation did not show alterations in cardiac parameters. In the HF group, muscles were observed to increase their +dT/dt (C: 52.6 ± 9.0 g/mm2/s and HF: 68.0 ± 17.0 g/mm2/s; p < 0.05). In addition, there was no changes in the cardiac expression of Ca2+ handling proteins. Conclusion: The initial moment of obesity promotes alterations to hormonal and lipid profiles without cardiac damage or changes in Ca2+ handling.


Resumo Fundamentos: Diferentes tipos de dietas hiperlipídicas e/ou hipercalóricas têm sido usados para induzir obesidade em roedores. No entanto, poucos estudos relataram os efeitos da obesidade induzida por dieta hiperlipídica em sua fase inicial sobre a remodelação cardíaca funcional e estrutural. Objetivo: Caracterizar o momento inicial da obesidade e investigar parâmetros metabólicos e cardíacos. Além disso, analisar o papel do trânsito de Ca+2 em curtos períodos de exposição à obesidade. Métodos: Ratos Wistar com idade de 30 dias foram distribuídos aleatoriamente em dois grupos (n = 19 em cada grupo): controle (C, dieta padrão) e dieta hiperlipídica (HL, dieta rica em gordura insaturada). O momento inicial da obesidade foi definido por medidas semanais do peso corporal, complementadas pelo índice de adiposidade (IA). A remodelação cardíaca foi avaliada por análise morfológica, histológica, ecocardiográfica e funcional dos músculos papilares. Proteínas envolvidas no trânsito de Ca2+ foram determinadas por Western Blot. Resultados: O momento inicial da obesidade ocorreu na terceira semana. Em comparação aos ratos C, os animais HL apresentaram maior peso corporal final (4%), gordura corporal (20%), IA (14,5%), níveis de insulina (39,7%), leptina (62,4%) e lipoproteína de baixa densidade (15,5%), mas não apresentaram alterações na pressão sistólica. A avaliação ecocardiográfica não mostrou alterações nos parâmetros cardíacos. No grupo HL, observou-se um aumento no +dT/dt (C: 52,6 ± 9,0 g/mm2/s e HL: 68,0 ± 17,0 g/mm2/s; p < 0,05) muscular. Além disso, não houve alterações na expressão cardíaca de proteínas envolvidas no trânsito de Ca2+. Conclusão: O momento inicial da obesidade promove alterações nos perfis hormonais e lipídicos sem causar danos cardíacos ou mudanças no trânsito de Ca2+.


Assuntos
Animais , Masculino , Ratos , Músculos Papilares/fisiopatologia , Cálcio/metabolismo , Comportamento Sedentário , Dieta Hiperlipídica , Obesidade/fisiopatologia , Obesidade/metabolismo , Músculos Papilares/metabolismo , Músculos Papilares/patologia , Pressão Sanguínea , Resistência à Insulina , Distribuição Aleatória , Western Blotting , Ratos Wistar , Modelos Animais de Doenças , Obesidade/etiologia , Obesidade/patologia
14.
Arq. bras. cardiol ; 105(6): 588-596, Dec. 2015. tab, graf
Artigo em Português | LILACS | ID: lil-769543

RESUMO

Abstract Background: Diet-induced obesity is frequently used to demonstrate cardiac dysfunction. However, some rats, like humans, are susceptible to developing an obesity phenotype, whereas others are resistant to that. Objective: To evaluate the association between obesity resistance and cardiac function, and the impact of obesity resistance on calcium handling. Methods: Thirty-day-old male Wistar rats were distributed into two groups, each with 54 animals: control (C; standard diet) and obese (four palatable high-fat diets) for 15 weeks. After the experimental protocol, rats consuming the high-fat diets were classified according to the adiposity index and subdivided into obesity-prone (OP) and obesity-resistant (OR). Nutritional profile, comorbidities, and cardiac remodeling were evaluated. Cardiac function was assessed by papillary muscle evaluation at baseline and after inotropic maneuvers. Results: The high-fat diets promoted increase in body fat and adiposity index in OP rats compared with C and OR rats. Glucose, lipid, and blood pressure profiles remained unchanged in OR rats. In addition, the total heart weight and the weight of the left and right ventricles in OR rats were lower than those in OP rats, but similar to those in C rats. Baseline cardiac muscle data were similar in all rats, but myocardial responsiveness to a post-rest contraction stimulus was compromised in OP and OR rats compared with C rats. Conclusion: Obesity resistance promoted specific changes in the contraction phase without changes in the relaxation phase. This mild abnormality may be related to intracellular Ca2+ handling.


Resumo Fundamento: A obesidade induzida por dieta é frequentemente utilizada para demonstração de disfunção cardíaca. No entanto, alguns ratos, como humanos, são suscetíveis ao desenvolvimento de um fenótipo de obesidade, enquanto outros são resistentes. Objetivo: Avaliar a relação entre resistência à obesidade e função cardíaca e o impacto da resistência à obesidade no trânsito de cálcio. Métodos: Ratos Wistar machos com trinta dias de idade foram distribuídos em dois grupos com 54 animais cada: controle (C; dieta padrão) e obesos (quatro dietas palatáveis hiperlipídicas) por 15 semanas. Após o protocolo experimental, os ratos alimentados por dietas hiperlipídicas foram classificados de acordo com o índice de adiposidade e subdivididos em propensos à obesidade (PO) e resistentes à obesidade (RO). Foram avaliados o perfil nutricional, comorbidades e remodelação cardíaca. A função cardíaca foi avaliada pelo estudo do músculo papilar isolado em condições basais e após manobras inotrópicas. Resultados: As dietas hiperlipídicas promoveram aumento na gordura corporal e no índice de adiposidade em ratos PO comparados com ratos C e RO. Os perfis de glicose, lipídios e pressão arterial permaneceram inalterados em ratos RO. Além disso, os ratos RO apresentaram peso total do coração e dos ventrículos direito e esquerdo mais baixos do que ratos PO, mas semelhantes aos ratos C. Os músculos cardíacos de todos os ratos apresentaram dados semelhantes na condição basal, mas a resposta miocárdica a um estímulo de contração pós-pausa estava comprometida em ratos PO e RO em comparação aos ratos C. Conclusão: A resistência à obesidade promoveu alterações específicas na fase de contração, sem alterar a fase de relaxamento. Esta anormalidade leve pode estar relacionada com o trânsito intracelular de Ca+2.


Assuntos
Animais , Masculino , Cálcio/metabolismo , Dieta Hiperlipídica , Contração Miocárdica/fisiologia , Obesidade/metabolismo , Adiposidade/fisiologia , Peso Corporal , Glicemia/análise , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Teste de Tolerância a Glucose , Resistência à Insulina , Tamanho do Órgão , Obesidade/fisiopatologia , Músculos Papilares/fisiopatologia , Ratos Wistar , Valores de Referência
15.
J. bras. patol. med. lab ; 49(4): 241-246, Aug. 2013. tab
Artigo em Inglês | LILACS | ID: lil-697097

RESUMO

B type natriuretic peptide (BNP) and its precursor, the inactive form of NT-pro-BNP, are currently the most studied laboratory parameters in the heart disease spectrum. The assessment of their blood concentrations provides invaluable information on the likelihood, severity and prognosis of the disease. The present review aims to describe the biological determinants, the factors that influence these peptide concentrations, the suggested cutoff values for the diagnosis of heart failure and the use of this biomarker in the assessment of cardiac function.


O peptídeo natriurético tipo B (BNP) ou o seu precursor, a forma inativa do fragmento N terminal do pró-BNP (NT-pró-BNP), são os parâmetros laboratoriais mais estudados atualmente no espectro da insuficiência cardíaca (IC). Por meio da mensuração de seus níveis no sangue, informações valiosas quanto a probabilidade, gravidade e prognóstico da doença podem ser reunidas. Esta revisão tem como objetivo descrever os determinantes biológicos, os fatores interferentes nas concentrações desses peptídeos, os valores de corte sugeridos para diagnóstico da IC e o uso deste biomarcador na avaliação da função cardíaca.

16.
J. bras. pneumol ; 39(4): 440-446, June-August/2013. tab
Artigo em Inglês | LILACS | ID: lil-686599

RESUMO

OBJECTIVE: To determine the probability of oxygen desaturation in healthy individuals undergoing the incremental shuttle walk test (ISWT). METHODS: We enrolled 83 healthy subjects: 55 males (including 1 smoker) and 28 females. We determined pre-ISWT FEV1, FEV6, HR and SpO2, as well as post-ISWT HR and SpO2. RESULTS: Mean values overall were as follows: age, 35.05 ± 12.53 years; body mass index, 24.30 ± 3.47 kg/m2; resting HR, 75.12 ± 12.48 bpm; resting SpO2, 97.96 ± 1.02%; FEV1, 3.75 ± 0.81 L; FEV6, 4.45 ± 0.87 L; FEV1/FEV6 ratio, 0.83 ± 0.08 (no restriction or obstruction); incremental shuttle walk distance, 958.30 ± 146.32 m; post-ISWT HR, 162.41 ± 18.24 bpm; and post-ISWT SpO2, 96.27 ± 2.21%. In 11 subjects, post-ISWT SpO2 was higher than was pre-ISWT SpO2. In 17 subjects, there was a 4% decrease in SpO2 after the ISWT. There were no statistically significant differences between the groups with and without post-ISWT oxygen desaturation in terms of age, gender, FEV1, FEV6, FEV1/FEV6, pre-ISWT SpO2, incremental shuttle walk distance, HR, or percentage of maximal HR. In the individuals with post-ISWT oxygen desaturation, the body mass index was higher (p = 0.01) and post-ISWT SpO2 was lower (p = 0.0001). CONCLUSIONS: Healthy individuals can present oxygen desaturation after the ISWT. Using the ISWT to predict subtle respiratory abnormalities can be misleading. In healthy subjects, oxygen desaturation is common after the ISWT, as it is during any intense physical activity. .


OBJETIVO: Determinar a probabilidade de dessaturação arterial em indivíduos saudáveis submetidos ao incremental shuttle walk test (ISWT). MÉTODOS: Foram estudados 83 indivíduos saudáveis, dos quais 55 eram homens (1 deles fumante) e 28 eram mulheres. Foram determinados VEF1 e VEF6 antes da realização do ISWT, assim como FC e SpO2 antes e depois do ISWT. RESULTADOS: As médias gerais foram as seguintes: idade, 35,05 ± 12,53 anos; índice de massa corporal, 24,30 ± 3,47 kg/m2; FC em repouso, 75,12 ± 12,48 bpm; SpO2 em repouso, 97,96 ± 1,02%; VEF1, 3,75 ± 0,81 L; VEF6, 4,45 ± 0,87 L; relação VEF1/VEF6, 0,83 ± 0,08 (sem restrição ou obstrução); distância percorrida no ISWT, 958,30 ± 146,32 m; FC pós-ISWT, 162,41 ± 18,24 bpm e SpO2 pós-ISWT, 96,27 ± 2,21% Em 11 indivíduos, houve um aumento da SpO2 após o ISWT, ao passo que em 17 houve uma queda de 4%. Não houve diferença estatística entre os grupos com e sem dessaturação após o ISWT no tocante às variáveis idade, gênero, VEF1, VEF6, VEF1/VEF6, SpO2 basal, distância percorrida no ISWT, FC e porcentagem da FC máxima. Nos indivíduos que apresentaram dessaturação, o índice de massa corporal foi maior (p = 0,01) e a SpO2 pós-ISWT foi menor (p = 0,0001). CONCLUSÕES: Indivíduos saudáveis podem apresentar dessaturação após o ISWT. O uso do ISWT para prever a presença de problemas respiratórios sutis pode ser enganador. Em indivíduos saudáveis, a dessaturação é um evento comum após o ISWT, assim ...


Assuntos
Adulto , Feminino , Humanos , Masculino , Teste de Esforço/métodos , Consumo de Oxigênio/fisiologia , Descanso/fisiologia , Caminhada/fisiologia , Estudos Transversais , Volume Expiratório Forçado/fisiologia , Valores de Referência
17.
Pesqui. vet. bras ; 32(supl.1): 47-52, Dec. 2012. ilus, tab
Artigo em Português | LILACS, VETINDEX | ID: lil-666068

RESUMO

A eletrocardiografia pode ser usada para quantificar o treinamento e o desempenho atlético. Pode ainda avaliar a função cardíaca sob efeito do exercício identificando a influência de anomalias cardíacas, assim como os efeitos deletérios do esforço frente à função cardíaca. Considerando a complexidade do esforço físico inerente a cavalos em competições de polo, juntamente com a carência de relatos na literatura sobre a demanda cardíaca resultante. O objetivo deste estudo foi o de identificar e avaliar eletrocardiograficamente os efeitos cardíacos do exercício de polo em equinos de forma a subsidiar dados para a compreensão da demanda fisiológica cardíaca desta modalidade. Foram avaliados 27 equinos praticante de polo em repouso e entre cinco e dez minutos após o exercício. Os resultados obtidos demonstraram que as alterações observadas na duração e amplitude da onda P e duração do intervalo PR e QT foram consideradas fisiológicas em resposta ao aumento da frequência cardíaca. A onda P difásica encontrada em repouso representou hipertrofia atrial e quando bífida representou diferentes pontos de ativação do nó sinoatrial. Como esperado o complexo QRS não sofreu alterações consideráveis entre os dois momentos. O supradesnível do segmento ST e as variações da onda T observadas após o exercício poderiam representar efeito adverso ao miocárdio, entretanto estudos analisando múltiplos fatores são necessários para confirmar esta associação e definir sua real causa. O aumento do QTc sugeriu fadiga miocárdica leve representando alta demanda cardíaca para esta modalidade. O escore cardíaco demonstrou que estes animais estavam dentro do padrão de adaptação cardíaca para um cavalo atleta. A rápida recuperação cardíaca demonstrou bom condicionamento atlético. O marca-passo atrial mutável foi um achado normal encontrado nos equinos de polo. Foi observada baixa incidência de alterações no ritmo cardíaco.(AU)


Electrocardiography can be used to quantify the training and athletic performance as well as evaluating the cardiac function under the effect of exercise identifying the influence of cardiac anomalies, and deleterious effects of stress ahead of heart function. Considering the complexity of the physical efforts inherent in polo ponies in competitions, together with the lack of reports in the literature, on the demand resulting for heart. The aim of this study was to identify and evaluate the cardiac effects of electrocardiographic exercise in polo horses in order to support data for understanding the physiological cardiac demand of this sport. We evaluated 27 equine practitioner polo at rest and between five and ten minutes after exercise. The results showed that the observed changes in the duration and P wave amplitude and duration of PR and QT interval were considered in physiological response to increased heart rate. The diphasic P wave found at rest and when atrial hypertrophy represented bifida represented different points of activation of the sinoatrial node. As expected, the QRS complex has not undergone major changes. The ST-segment elevation and T wave changes observed after exercise could pose adverse effects to the myocardium, but studies examining multiple factors are needed to confirm this association and define your actual question. The increase in QTc suggested fatigue mild myocardial represented high heart demand for this type of exercise. The heart score showed that these animals were within the pattern of cardiac adaptation to a horse athlete. The rapid recovery of HR showed good conditioning of these animals. The pacemaker migration was observed in most animals proven to be a normal finding horse athlete. We observed a low incidence of changes in cardiac rhythm.(AU)


Assuntos
Animais , Exercício Físico , Eletrocardiografia/métodos , Esforço Físico , Cavalos/fisiologia
18.
Pesqui. vet. bras ; 32(12): 1336-1340, Dec. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-662568

RESUMO

The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE) is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%), strain rate (1/s), displacement (mm) and velocity (cm/s), respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quantification of myocardial function in this species.


A obtenção de parâmetros cardiovasculares em animais selvagens são importantes de serem avaliados, assim como em animais de companhia, para a obtenção da função miocárdica e determinação precoce de alterações cardíacas que poderiam evoluir para insuficiência cardíaca . A ecocardiografia speckle tracking (2D STE) é uma ferramenta nova que tem sido utilizada em medicina veterinária, a qual tem demonstrado várias vantagens quanto ao seu uso, como a independência do ângulo de insonação e a possibilidade de se obter o diagnóstico precoce de alterações miocárdicas. Objetivou-se avaliar a função miocárdica esquerda de um lobo guará por meio do uso da 2D STE. Desta forma, foram obtidas as variáveis Strain e Strain Rate longitudinais, circunferenciais e radiais, assim como a velocidade e o deslocamento longitudinais e radiais, utilizando os cortes eixo longo paraesternal direito quatro câmaras, paraesternal esquerdo apical quatro câmaras e eixo curto paraesternal direito no plano dos músculos papilares. Os resultados das variáveis longitudinais fora -13,52±7,88, -1,60±1,05, 4,34±2,52 e 3,86±3,04 para Strain (%), Strain rate (1/s), deslocamento (mm) e velocidade (cm/s), respectivamente. Quanto ao Strain e Strain rate radiais e circunferenciais foram obtidos 24,39±14,23, 1,86±0,95 e -13,69±6,53, -1,01±0,48. Portanto, o presente estudo fornece os primeiros dados a respeito do uso desta ferramenta em lobos guarás, permitindo uma quantificação da função miocárdica de forma mais completa nesta espécie.


Assuntos
Animais , Biometria , Ecocardiografia/veterinária , Ventrículos do Coração , Lobos/anatomia & histologia , Cardiomiopatias , Cardiomiopatias/veterinária
19.
Pesqui. vet. bras ; 32(11): 1191-1195, Nov. 2012. tab
Artigo em Português | LILACS | ID: lil-658092

RESUMO

Considerando a complexidade do esforço físico inerente a cavalos em competições de polo e da carência de relatos na literatura sobre os efeitos cardíacos resultantes de um chukker, associado ainda a dinâmica do peso, o objetivo deste estudo foi de avaliar por meio da ecocardiografia, 27 equinos atletas de polo, submetidos à partida treino, em repouso e após o exercício. Os resultados demonstraram que esta modalidade alterou diversos índices ecocardiográfico no período de cinco a dez minutos do término de um chukker. Foram eles, estruturais com: redução da espessura do septo interventricular e parede livre do ventrículo esquerdo e aumento do diâmetro interno do ventrículo esquerdo em sístole, e funcionais como: aumento do débito cardíaco e frequência cardíaca, enquanto que o volume sistólico, a fração de encurtamento e a fração de ejeção reduziram. A perda de peso corporal não foi significativa, portanto não foi associado às alterações ecocardiográficas. Estes resultados sugeriram que a demanda cardíaca foi alta, indicando a importância de um acompanhamento físico e treinamento cardiovascular específico para esta modalidade.


Considering the complexity of the physical effort inherent in polo horses in competitions and the lack of reports about the cardiovascular effects resulting from a Chukker, yet the dynamics of the associated weight, the aim of this study was to evaluate by echocardiography with 27 horses polo athletes who underwent training starting at rest and after exercise. The results showed that this method has changed several echocardiographic indexes within five to ten minutes before the end of a Chukker. It was they, as structural index, thickness reduction interventricular septum and left ventricular free wall and increased left ventricular diameter, and functional as an increase in cardiac output and heart rate, while stroke volume, fractional shortening and ejection fraction reduced. The weight loss was not significant, so was not associated with echocardiographic changes. These results suggest that cardiac demand was high, indicating the importance of the physical and cardiovascular training specific to this modality.


Assuntos
Animais , Cavalos/fisiologia , Ecocardiografia sob Estresse/veterinária , Esforço Físico , Frequência Cardíaca , Corrida
20.
Acta cir. bras ; 25(6): 535-540, nov.-dez. 2010. graf, tab
Artigo em Inglês | LILACS | ID: lil-567285

RESUMO

PURPOSE: To assess whether the tests - Forced Expiratory Volume at one second (FEV1), 6-minute walk test (6MWT) and stair-climbing test (SCT) showed proportional changes after the resection of functioning lung. METHODS: Candidates for pulmonary resection were included. Spirometry, 6MWT and SCT were performed preoperatively (pre) and at least 3 months after surgery (pos). SCT was performed on a staircase with a total ascent height of 12.16m. The time taken to climb the total height the fastest possible was defined as stair-climbing time (SCt). Number of functioning segments lost, was used to calculated predicted postoperative (ppo) tests values. Pre, ppo and pos values for each test were compared. Data were analyzed by repeated-measure ANOVA with significance level set at 5 percent. RESULTS: A total of 40 patients were enrolled. Pulmonary resection results ranged from gain of 2 functioning segments to loss of 9. Pre, ppo and pos values were the following: preFEV1 = 2.6±0.8L, ppo FEV1 =2.3±0.8L, and pos FEV1=2.3±0.8L, (pre FEV1 > ppo FEV1 = pos FEV1); pre6MWT = 604±63m, ppo6MWT= 529±103m, pos6MWT= 599±74m (pre6MWT = pos6MWT > ppo6MWT); preSCt = 32.9±7.6s, ppoSCt = 37.8±12.1s, posSCt = 33.7±8.5s (preSCt = posSCt < ppoSCt). CONCLUSION: In our group of patients, pulmonary resection led to loss of lung function measured by spirometry, but not to exercise capacity measured by stair-climbing and walk tests.


OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5 por cento. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Teste de Esforço , Tolerância ao Exercício/fisiologia , Volume Expiratório Forçado/fisiologia , Pulmão/cirurgia , Caminhada/fisiologia , Análise de Variância , Pulmão/fisiopatologia , Período Pós-Operatório , Cuidados Pré-Operatórios , Espirometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...